Home / Questions / hot industrialwaste water at 15 bar 180 Celsius with a mass flow rate of 5 kg/s enters a f...

hot industrialwaste water at 15 bar 180 Celsius with a mass flow rate of 5 kg/s enters a flash chamber via a valve Saturated

hot industrialwaste water at
15 bar, 180 Celsius with a mass flow rate of 5 kg/s enters a flash
chamber via a valve. Saturated vapor and saturated liquid
streams, each at 4 bar, exit the flash chamber. The saturated
vapor enters the turbine and expands to 0.08 bar, x = 90%.
Stray heat transfer and kinetic and potential energy effects
are negligible. For operation at steady state, determine the
power, in hp, developed by the turbine.