Create an Account

Already have account?

Forgot Your Password ?

Home / Questions / A process liquid is pumped from a storage tank to a distillation column using a centrifuga...

A process liquid is pumped from a storage tank to a distillation column using a centrifugalpump The pipeline is 80 mm internal diameter commercial steel pipe 100 m long Miscellaneous losses are

A process liquid is pumped from a storage tank to a distillation column, using a centrifugalpump. The pipeline is 80 mm internal diameter commercial steel pipe, 100 m long.Miscellaneous losses are equivalent to 600 pipe diameters. The storage tank operates atatmospheric pressure and the column at 1.7 bara. The lowest liquid level in the tank will be1.5 m above the pump inlet, and the feed point to the column is 3 m above the pump inlet.Plot the system curve on the pump characteristic given in Figure A and determine theoperating point and pump efficiency.Properties of the fluid: density 900 kg/m3, viscosity 1.36 mN m2s.

 

Jul 25 2020 View more View Less

Answer (Solved)

question Subscribe To Get Solution

Related Questions